Greyline AVFM-II Area-Velocity
Flow Monitor
Standard features include:
- QZ02L sensor – measures flow Velocity and
Level
- sensor cable – 25 ft / 7.6 m submersible,
shielded 3-coaxial
- enclosure - watertight, NEMA4X (IP66) polycarbonate
- displays - Flow Rate - large 4-digit LCD
- Totalizer/Menu/Status - 16-digit alphanumeric
- calibration - built-in 3-key programmer
- output – three isolated 4-20mA (1000 ohm),
Flow, Level and Velocity
- 2 control relays - 5 amp, SPDT - programmable
for flow
proportional pulse output, flow and/or level alarm
- power input - 100-160VAC 50/60Hz
- electrical surge protection and RFI filters
- AC, sensor, 4-20mA
- 1 Manual - Installation and Operation
AREA-VELOCITY FLOW MONITOR SPECIFICATIONS
SCOPE: This specification covers an ultrasonic,
area-velocity flow monitor as manufactured by Greyline Instruments, Massena,
New York / Long Sault, Ontario. The instrument shall provide for indicating,
transmitting, totalizing of the flow rate through partially filled or surcharged
round pipes or rectangular, trapezoidal and egg-shaped channels.
A. GENERAL
- Flow Monitor to consist of a submersible
ultrasonic sensor, connecting cable, and remote enclosure with indicating,
transmitting and controlling electronics. System shall have no moving parts.
- Level measurement accuracy shall be ±0.25%
of Range. Velocity measurement accuracy shall be ±2% of reading.
B. SENSING ELEMENT
- Ultrasonic sensor shall be designed for continuous
submersion in liquids.
- Using the Doppler principle, the sensor shall
measure fluid velocities from 0.1 to 20 ft/sec (0.03 to 6.2 m/sec).
- Using ultrasonic echo-ranging principle,
the submerged sensor shall measure liquid level from 1" to 15 ft.
(25.4 mm to 4.57 m). Minimum level shall not be greater than 1" (25.4
mm). Level sensing circuitry shall include a temperature sensor for automatic
temperature compensation.
- Sensor shall be constructed of PVC and epoxy
resin.
- Sensor operating temperature shall be 5°F
to 150°F (-15°C to 65°C).
C. SENSOR CONNECTING CABLE
- Provide minimum length 25 ft (7.6 m) tri-coaxial
cable with potted bond to the Sensor head. Sensor cable shall be waterproof
and electrically shielded. Exposed material shall be polyurethane only.
- Extended sensor cable shall be shielded tri-coaxial
to a maximum length of 500 ft (152m). Cable shall be spliced with screw
terminal connections in manufacturer’s recommended steel NEMA4 Junction
Box.
D. TRANSMITTER
- The transmitter shall provide for field calibration
to round pipes, rectangular, trapezoidal and egg-shaped channels.
- Calibration shall be via built-in 3-key calibration
system with menu selection of parameters. Systems requiring calibration
by Parameter codes, BCD switches or external calibrators shall not be accepted.
- Calibration data shall be password protected
and permanently stored through power interruptions for a minimum of 12
months.
- Field calibration shall allow selection and
automatic conversion of measurement units, measurement span, high/low flow
alarm relay and flow proportional relay pulse rates.
- Transmitter shall permit field programmable
damping to smooth output in turbulent flow conditions, and programmable
rejection time to disregard false signals from rain, wind, floating objects
and spurious echoes.
- Transmitter operating temperature shall be
from -5° to 140°F (-20° to 60°C). Transmitter shall contain a thermostat-controlled
enclosure heater for condensation protection below 30°F (-1°C).
- Transmitter shall have three isolated 4-20mA
outputs rated for 1000 ohm maximum load. Outputs shall be configured to
transmit level, velocity and flow.
- Provide two relay contacts rated 5 amp SPDT
programmable for flow proportionate pulse to a remote totalizer or sampler,
high-low flow, velocity and/or level alarm, echo loss alarm.
- Provide a 4-digit LCD display scaled in user-selected
engineering units and visible without opening the Transmitter enclosure.
- Provide a 16-digit alphanumeric display for
calibration menu, running totalizer, flow reports and operation messages.
- Transmitter shall be housed in a wall-mount,
watertight NEMA4X (IP66) enclosure with hinged, clear cover. Mounting hardware
shall be included.
- Transmitter Displays indicating flow rate,
units of calibration, maximum flow rate and flow totalizer shall be visible
without opening cover.
- Transmitter electronics shall be surge protected
on AC power input, sensor and 4-20mA outputs.
- Transmitter power input shall be 115VAC 50/60Hz
with power consumption of 8.5 watts or less.
E. OPTIONAL FEATURES FOR INSERTION AS REQUIRED
Sensors
- Have separate, submerged Doppler velocity
sensor, plus a non-contacting ultrasonic level sensor mounted above the
liquid. Doppler velocity sensor shall be designed for continuous submersion
in liquids and rated for fluid velocities from 0.1 to 20 ft/sec (0.03 to
6.2 m/sec). Non-contacting ultrasonic level sensor shall be rated for measurement
range from 8" to 12 ft. (203.2 mm to 3.66 m) and shall include integral
temperature compensation.
- Sensor cable shall be 50 ft. (15 m) continuous
length with potted bond to the Sensor head.
- Sensor cable shall be 100 ft. (30 m) continuous
length with potted bond to the Sensor head.
- Separate length extended sensor cable shall
be shielded tri-coaxial to a total maximum length of 500 ft (152m). Cable
shall be spliced with screw terminal connections in manufacturers recommended
steel NEMA4 Junction Box.
- Sensor and connecting cable shall be rated
intrinsically safe to Class I,II,III, Div. I,II, Groups C,D,E,F,G for installation
in hazardous locations.
- Sensor shall mount with manufacturer's stainless
steel mounting band for specified pipe diameter from 6" to 72" (150
to 1800 mm).
Electronics
- Have a built-in 50,000 point data logger,
RS232 serial output and connecting cables. Data logger shall support time
and date-stamped logging and generate formatted flow reports including
total, average, minimum, maximum and times of occurrence. Include Windows
software for data log retrieval, graphing and export.
- Have a thermostat controlled enclosure heater
for Transmitter operation at temperatures below freezing.
- Have manufacturer's recommended enclosure
sunscreen to permit Electronics enclosure mounting in direct sunlight.
- Transmitter power input shall be 200-260VAC
50/60Hz with maximum power consumption of 8.5 watts or less.
- Transmitter power input shall be 9-36VDC
with minimum power consumption of 2.9 watts.
F. MANUFACTURER
Area-Velocity Flow Monitor shall be Greyline
Model AVFM-II and warranted against defects in materials and workmanship
for one year.