AVFM-II Area-Velocity Flow Monitor
For Open Channels and Pipes
Ultrasonic - Measures Velocity + Level to Calculate Flow
No Flume or Weir required
3 Isolated 4-20mA Outputs (Flow, Level and Velocity)
Totalizer and 2 Programmable Control Relays
Simple 3-key Calibration - Password Protected
Optional Intrinsically Safe Sensor
Optional built-in 50,000 point Data Logger and Software
AVFM Area-Velocity Flow Monitor
Monitor flow through open channels, partially full sewer pipes and surcharged pipes without a flume or weir. Ideal for stormwater, combined effluent, raw sewage, irrigation water and streams. The AVFM-II uses a submerged ultrasonic sensor to continuously measure both Velocity and Level in the channel. The sensor is a completely sealed ultrasonic unit with no orifices or ports. It mounts inside a pipe or at the bottom of a rectangular, trapezoid or egg-shaped channel. Calibration is simple: enter the pipe diameter or channel width and the AVFM-II computes the flow volume and displays the flow rate.